1. POWER FACTOR CONTROLLER: Digital/6-Steps
With Continuous Digital Power Factor Display
Type : B6 6 Steps
SPECIFICATIONS:
i.
Power Supply & Measurement voltage: 230V±15% OR 400V±15%
ii. Connection : with or without Neutral Line i.e. LN=Phase to
Neutral or LL=Phase to Phase
iii. Frequency : 50 or 60Hz ± 1Hz, automatic selection
iv. Operation Sequence : user selectable from menu
normal 1: 2: 4: 4; stack 1: 1: 1: 1:
circulating A 1: 1: 1: 1; circulating B 1: 2: 2: 2:
v. Output Relay : N.O., Contact Ratings: 2.0A/400VAC
vi. Alarm Relay : N.O., Contact Ratings: 2.0A/400VAC
vii. Ambient Temperature : 0 to 50 C
viii. Size : 144 x 144 x 60mm, Protection Class : IP40
ix. Step Reconnection Delay : Adjustable from 10 to 300 secs
FEATURES:
-
Three digit LCD Display with graphical symbols for continuous
display of Power Factor and setting & display of 8 different
functions selection modes.
-
Automatic search of C/K values. C/K setting and display 0.00
… 1.99.
-
Easy to use menu-driven user interface.
-
Automatic Polarity adjustment of CT connection.
-
Separate alarm relay with potential free terminals.
-
All steps are released at voltage dropout.
-
Number of steps setting and display 1 … 6.
-
Manual stepping setting and display.
-
Plug in connectors at rear side.
-
State of art microprocessor technology.
2. POWER
FACTOR CONTROLLER: Digital/12 Steps with Alarms
with Continuous Digital Power Factor & Capacitor Steps Display.
Type : A12 12 Steps
SPECIFICATIONS:
i. Power Supply
: 230V±15%
ii. Measurement Voltage : 230V±15% OR 400V±15%
iii. Connection : with or without Neutral Line i.e. LN=Phase to
Neutral or LL=Phase to Phase
iv. Frequency : 50 or 60Hz ± 2Hz, automatic selection.
v. Operation Sequence : user selectable from menu
normal 1: 2: 4: 4; stack 1: 1: 1: 1:
circulating A 1: 1: 1: 1; circulating B 1: 2: 2: 2:
vi. Output Relay : N.O., Contact Ratings: 2.0A/400VAC
vii. Alarm Relay : N.O., Contact Ratings : 2.0A/400VAC
viii. Accuracy Class : 1.5%
ix. Ambient Temperature : 0 to 50 C
x. Size : 144 x 144 x 60mm, Protection Class : IP40
xi. Step Reconnection Delay : Adjustable from 10 … 900 secs.
FEATURES:
- 16 Character
alphanumeric LCD with graphical symbols, for continuous display
of Power Factor and Capacitor steps.
- Power Factor
display 0.00 ind. … 1.00 … 0.00 cap.
- LED display
for alarm and ind/cap.
- CT ratio
settings and display : 100/5 … 6000/5.
- Target PF
setting and display : 0.80 ind … 1.00 … 0.90 cap.
- Setting
and display of step sizes : 10 … 1000 KVAR
- Setting
and display of input voltage : 80 … 460V.
- Automatic
search of C/K values. C/K setting and display 0.00 … 1.99.
- Easy to
use menu-driven user interface.
- Automatic
Polarity adjustment of CT connections.
- Separate
alarm relay with potential free terminal.
- Following
Alarms can be selected (enable/disable and status) low power factor,
hunting, abnormal cos ø, undervoltage, overcapacitive,
wrong frequency, overcurrent, overvoltage, overtemperature, voltage
harmonic distortion (THD), capacitor overload and capacitor output
low.
- All steps
are released at voltage dropout.
- Number of
steps setting and display 1 … 12.
- Manual stepping
setting and display.
- Fixed stepping
setting and display.
- Plug in connectors
at rear side.
- State of
art microprocessor technology.
Also available:
Type: B12/12 Steps
With Continuous Power Factor & Capacitor Steps Display
(Note: B12 is same as Type A12, but without Alarm function)
[